100 KVA Ashlok Leyland Diesel Generator
100 KVA Ashlok Leyland Diesel Generator Specification
- Dimension (L*W*H)
- 3250 mm x 1200 mm x 1600 mm
- Bore *Stroke
- 104 mm X 113 mm
- Fuel Consumption
- 17-18 Ltr/hr at full load
- Fuel Tank Capacity
- 200 Litres
- Engine Model
- Ashok Leyland AL6DTI25
- Pressure
- Compression Ratio 17:1
- Protection Class
- IP23
- Poles Number
- 4
- Standard
- Complies with CPCB II Emission Norms
- Engine Type
- 4 Stroke, Turbocharged, Diesel Engine
- Alternator
- Stamford / Crompton / Equivalent
- Insulation
- Class H
- Product Type
- Ashlok Leyland Diesel Generator
- Output Type
- AC
- Rated Power
- 100 kVA
- Rated Voltage
- 220-415 Volt (V)
- Starting Type
- Electric Start
- Rated Frequency
- 50 Hz
- Power Range
- 100 KVA
- Color
- White & Blue
- Cooling System
- Water Cooled
- Noise Level
- Silent (Super Silent canopy)
- Phase
- Three Phase
- Speed
- 1500 RPM
- Weight
- Approx. 1800 kg
- Mounting
- Base frame on anti-vibration mounting
- Relative Humidity
- Up to 90% Non-Condensing
- Fuel Type
- High speed diesel
- Alternator Type
- Brushless, Self Excited
- Voltage Regulation
- 1% (Automatic Voltage Regulator)
- Display
- Digital Meter for Ammeter, Voltmeter, Frequency, Hour Meter, Fuel Level
- Control Panel
- Auto/Manual with AMF capability
- Lubrication System
- Forced lubrication
- Exhaust System
- Industrial silencer in canopy
- Standards Complied
- IS 4722, BS 5000, IEC 34/IS 13364
- Battery
- 12V lead acid maintenance free
- Ambient Temperature
- Up to 50C
- Overload Protection
- Provided
100 KVA Ashlok Leyland Diesel Generator Trade Information
- Minimum Order Quantity
- 1 Unit
- Supply Ability
- 200 Units Per Month
- Delivery Time
- 10 Days
About 100 KVA Ashlok Leyland Diesel Generator
Industrial Powerhouse: Unmatched Application & Advantages
The 100 KVA Ashlok Leyland Diesel Generator is tailored for plant operations, heavy-duty industries, commercial complexes, and critical infrastructure. Use it for continuous power supply in factories, hospitals, and large construction sites. Its primary advantages include robust overload protection, digital monitoring, noiseless operation, and compliance with CPCB II Emission Norms. The generator stands out with high efficiency, minimal vibration, and enduring performance, ensuring reliable support for your mission-critical operations.
Export Market Ready: Sample Policy & Certifications
We cater to the export market with a straightforward sample policy and comprehensive Purchase Order processing. The generator ships from a designated Indian FOB port with secure packaging to prevent transit damage. Certifications like IS 4722, BS 5000, and IEC 34/IS 13364 accompany each unit, attesting to rigorous quality standards. Our timely delivery and detailed documentation make the purchasing process seamless for international and domestic clients alike.
FAQ's of 100 KVA Ashlok Leyland Diesel Generator:
Q: How does the automatic voltage regulator benefit my operations?
A: The automatic voltage regulator maintains output voltage within a tight 1% range, safeguarding sensitive equipment from voltage fluctuations and ensuring stable and consistent performance for your machinery.Q: What industries commonly use the 100 KVA Ashlok Leyland Diesel Generator?
A: This generator is ideal for manufacturing plants, construction sites, hospitals, commercial complexes, and infrastructure projects where continuous, reliable, and silent power is essential.Q: Where can the generator be installed for optimal performance?
A: The generator can be installed on a sturdy anti-vibration mounting base in open or enclosed industrial environments, thanks to its super silent canopy and robust protection class.Q: What is the process for placing a Purchase Order and receiving the unit?
A: Simply place an Order Today via our platform. We process the purchase, arrange secure packaging, and ship from an Indian FOB port. Certifications and export documentation are included for hassle-free delivery.Q: What are the maintenance requirements and usage benefits of this generator?
A: Minimal maintenance is needed due to its forced lubrication, maintenance-free battery, and water-cooled system. Users benefit from digital monitoring, overload protection, high energy efficiency, and compliance with international emission norms.
- Minimum Order Quantity
- 1 Unit
- Supply Ability
- 200 Units Per Month
- Delivery Time
- 10 Days
Price:
- 50
- 100
- 200
- 250
- 500
- 1000+
More Products in Ashok Leyaland Diesel Generator Category
200 KVA Ashlok Leyland Diesel Generator
Price Range 1000000.00 - 10000000.00 INR / Unit
Minimum Order Quantity : 1 Unit
Rated Voltage : 220415 Volt (V)
Protection Class : IP 23
Starting Type : Electric Start
Color : Other, White & Blue
45 KVA Ashlok Leyland Diesel Generator
Price Range 100000.00 - 1000000.00 INR / Unit
Minimum Order Quantity : 1 Unit
Rated Voltage : 220415 Volt (V)
Protection Class : IP23
Starting Type : Electric Start
Color : Other, White & Blue
125 KVA Ashlok Leyland Diesel Generator
Price Range 1000000.00 - 10000000.00 INR / Unit
Minimum Order Quantity : 1 Unit
Rated Voltage : 220415 Volt (V)
Protection Class : IP 23
Starting Type : Electric Start
Color : Green
82.5 KVA Ashlok Leyland Diesel Generator
Price Range 1000000.00 - 10000000.00 INR / Unit
Minimum Order Quantity : 1 Unit
Rated Voltage : 220415 Volt (V)
Protection Class : IP23
Starting Type : Electric Start
Color : Green
![]() |
SUN POWER SOLUTION
All Rights Reserved.(Terms of Use) Developed and Managed by Infocom Network Private Limited. |