Cummins CPCB IV 125 kva Generator
Cummins CPCB IV 125 kva Generator Specification
- Engine Type
- 4 Stroke, Inline, Turbocharged
- Poles Number
- 4
- Fuel Tank Capacity
- 220 Litres
- Dimension (L*W*H)
- 2950 mm x 1100 mm x 1500 mm
- Standard
- CPCB IV+
- Engine Model
- Cummins QSB5.9-G4
- Pressure
- 17.5:1 (Compression Ratio)
- Fuel Consumption
- ~28 Ltr/hr at 100% load
- Bore *Stroke
- 102 mm x 120 mm
- Protection Class
- IP23
- Insulation
- Class H
- Alternator
- Stamford / Cummins Reconned
- Product Type
- Diesel Generator
- Output Type
- AC
- Rated Power
- 125 kVA
- Rated Voltage
- 415 Volt (V)
- Starting Type
- Electric Start
- Rated Frequency
- 50 Hz
- Power Range
- 125 kVA
- Color
- Green
- Cooling System
- Water Cooled
- Noise Level
- <75 dB(A) @ 1m
- Phase
- Three Phase
- Speed
- 1500 RPM
- Weight
- Approx. 2100 kg
- Ambient Temperature
- Up to 50C
- Cooling Water Capacity
- 22 Litres
- Exhaust Emission
- Complies with CPCB IV+ norms
- Lubrication Oil Change Period
- 250 hours or as per manual
- Relative Humidity
- Up to 95% (non-condensing)
- Battery Capacity
- 12V, 150 Ah
- Altitude
- Up to 1000 m above sea level without derating
- Residual Voltage
- <5% of rated voltage
- Governor Type
- Electronic Governor
- Display
- Multi-function LCD panel
- Overload Capacity
- 10% for 1 hour in 12 hours
- Service Accessibility
- One side servicing access
- Controller
- Microprocessor based digital controller
- Excitation
- Self-excited, Brushless, AVR Controlled
- Regulation
- Voltage regulation 1% (No load to full load)
Cummins CPCB IV 125 kva Generator Trade Information
- Minimum Order Quantity
- 1 Number
- Supply Ability
- 10 Per Month
- Delivery Time
- 1-7 Days
About Cummins CPCB IV 125 kva Generator
Application Method and Direction of Use
The Cummins CPCB IV 125 kVA Generator is expertly designed for industrial plants and commercial establishments, ensuring a steady, uninterrupted AC power supply. For optimal operation, install the generator on a flat surface in a ventilated area, following the plant's safety protocols. Regularly check and refill fuel, oil, and water as per the user manual. Its electric start allows swift activation, while the intuitive LCD display guides monitoring and management.
Secure Delivery and Global Market Valuation
Each generator is delivered with secure shipping protocols, carefully packed and transported to prevent damage. Valued by industries nationwide and internationally, prompt delivery times are ensured to major export markets including Asia, Middle East, and Africa. With dispatch from Indian FOB ports, buyers receive their units safely and efficiently, meeting project deadlines and operational needs every time. Experience unparalleled reliability from order to arrival.
FAQ's of Cummins CPCB IV 125 kva Generator:
Q: How does the Cummins CPCB IV 125 kVA Generator ensure consistent power output?
A: The generator uses a self-excited, brushless, AVR-controlled alternator with a sophisticated microprocessor-based digital controller, ensuring steady voltage regulation (within 1%) from no load to full load conditions.Q: What is the recommended process for plant installation and commissioning?
A: Install the generator on a stable, level surface with adequate ventilation. Follow all safety and operational instructions in the manual for connecting cables, filling fluids, and starting the generator. Regular maintenance, including oil and water checks according to the service intervals, ensures longevity.Q: Where can this generator be used effectively?
A: It is ideal for factories, commercial complexes, construction sites, and other large-scale plant applications requiring consistent high-capacity power. Its compliance with CPCB IV+ standards makes it suitable for environmentally regulated zones.Q: When should lubrication oil be changed?
A: The lubrication oil should be changed every 250 operating hours or as directed in the user manual, promoting optimal engine performance and durability.Q: What are the main benefits of the electronic governor and advanced cooling system?
A: The electronic governor ensures precise engine speed control and stable power output, while the 22-litre water cooling system maintains optimal engine temperatures, allowing reliable operation even in extreme ambient conditions up to 50C.Q: How is generator performance monitored during use?
A: Performance is monitored via a multi-function LCD panel, which displays crucial parameters like voltage, current, temperature, and operational hours, enabling proactive maintenance and management.
- Minimum Order Quantity
- 1 Number
- Supply Ability
- 10 Per Month
- Delivery Time
- 1-7 Days
Price:
- 50
- 100
- 200
- 250
- 500
- 1000+
More Products in Cummins Diesel Generator Category
Cummins CPCB IV 225 kva Generator
Price Range 1000000.00 - 3000000.00 INR / Number
Minimum Order Quantity : 1 Number
Weight : 2850 kg (approx.)
Alternator : Stamford / Cummins Make, Brushless
Insulation : Class H
Bore *Stroke : 140 mm x 152 mm
Cummins CPCB IV 1500 kva Generator
Price Range 1000000.00 - 5000000.00 INR / Number
Minimum Order Quantity : 1 Number
Weight : Approx. 13900 kg
Alternator : Stamford, Brushless
Insulation : Class H
Bore *Stroke : 159 mm x 190 mm
Cummins CPCB IV 250 kva Generator
Price Range 1000000.00 - 3000000.00 INR / Number
Minimum Order Quantity : 1 Number
Weight : ~3200 kg
Alternator : Stamford/Equivalent
Insulation : Class H
Bore *Stroke : 130 mm x 163 mm
Cummins CPCB IV 58.5 kva Generator
Price Range 1000000.00 - 1000000.00 INR / Number
Minimum Order Quantity : 1 Number
Weight : 1200 kg
Alternator : Stamford / Crompton Greaves
Insulation : Class H
Bore *Stroke : 102 x 120 mm
![]() |
SUN POWER SOLUTION
All Rights Reserved.(Terms of Use) Developed and Managed by Infocom Network Private Limited. |